Sign In | Join Free | My components-electronic.com
components-electronic.com
Products
Search by Category
Home > Construction Machinery Parts >

Truck Crane Load Cell Indicator Tensioner System Safe Load Indicator Lmi

Categories Automatic Safe Load Indicator
Brand Name: RECEN
Model Number: RC-105
Certification: CE, ISO9001, SGS
Place of Origin: China
MOQ: 1
Price: Negotiable
Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability: 2000 SETS / YEAR
Delivery Time: 5-10 days
Packaging Details: Cartons
Type: Truck Scale,Control indicator,digital load indicator luggage scale,Bench Scale,Load cell with indicator
Rated load: Under 100 tons
Warranty: 12 Months
Name: Weight Indicator,china weighing indicator
Function: Weight Function,With Tare & Net Weight Setting
Operating temperature: -20~+60 ℃
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

Truck Crane Load Cell Indicator Tensioner System Safe Load Indicator Lmi

Truck Crane Load Cell Indicatortensioner System Safe Load Indicator Lmi


System Profile


Signal inspection(The signal is correct in order to debug)


1.Angle sensor signal inspection,Look at the RAD in the main interface:Data,It is proportional to the size of the arm's elevation angle.;


2. Weight sensor signal check, in the main interface to view the data of WAD:, it will be proportional to the weight of the hanging.;


3.The length sensor signal is checked and the LAD: data is viewed in the main interface. It will be proportional to the elongation and retraction of the boom;


Product feature


·Do not pull cable at will, prevent breakage and break. When you need to dismantle the whole machine, you should pay attention to protecting the connecting plugs, so as not to pollute and affect the use.


·Non maintenance personnel shall not arbitrarily adjust the internal parameters of the instrument, such as abnormal, first according to the method provided in the instructions, if the failure can not be ruled out, please report to the relevant personnel.


·After the crane's working condition is changed, please change the crane working condition parameter in time, so that the crane can work normally


·This device can not prevent accidents caused by dangerous factors (not according to safety regulations). Therefore, the safety operation rules should not be neglected due to the installation of this device


·Regularly check the system accuracy (cycle 4 to 6 months) to ensure the safe use of cranes.


  • Working voltage: DC24V / DC12V
    Working environment temperature: - 20 C ~ + 60 C
    Relative humidity: < 95% (25 C)
    Mode of work: continuous
    Whole machine power consumption: < 20W
    Control output capacity: DC24V/1A;
    Resolution: 0.1t
    System synthesis error: <5%
    Alarm error: <3%

Quality Truck Crane Load Cell Indicator Tensioner System Safe Load Indicator Lmi for sale
Send your message to this supplier
 
*From:
*To: Chengdu Recen Technology Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0