Low Current Three Phase Soft Starter , High Torque Soft Starter For Air Conditioner Compressor

Categories Bypass Soft Starter
Brand Name: Noker
Model Number: RJ-ASSU380KW22
Certification: ISO9001
Place of Origin: China
MOQ: 1 set
Price: To be discussed later
Payment Terms: L/C, T/T, Western Union
Supply Ability: 2000 set per month
Delivery Time: 5-8 work days
Packaging Details: Carton Packing
Dimension: Small Size, Light Weight
Torque: Low current and high torque
Installtion: Easy to wire and install
Reliability: High reliability and long life
Current surges & voltage drops: Eliminates current surges & voltage drops
Motor/compressor service life: Extends motor/compressor service life
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
  • Submit Buying Request
    • Product Details
    • Company Profile

    Low Current Three Phase Soft Starter , High Torque Soft Starter For Air Conditioner Compressor

    Three Phase AC380V KW22 Low Current High Torque Electric Motor Air Conditioning Compressor/Heat Pump Soft Starter


    RJ-RSSU380KW22 provides an effective solution in reduction of start-up current, typically up to 70%, but still provides full startup torque for compressors and motors. Across the line starting of air-conditioner compressor or induction motors is accompanied by inrush currents up to 7-8 times higher than running current, and starting torque up to 3 times higher than running torque. The increased unnecessary torque results in sudden mechanical stress on the machine which leads to increased wear and higher service costs and reduced service life. Moreover, the high inrush current and current peaks may stress the power supply system to increased mains and generator loads which may lead to voltage dips results in breaking down of other valuable equipment or system function.

    RJ-RSSU380KW22 is an embedded design soft start controller. It regulates the start-up voltage of the compressor/motor intelligently to effectively reduce the inrush and surge current while starting-up, thus consume much less power from the public utility network or on-site AC power supply system but still provides full startup torque for compressors and motors. RJ-RSSU380KW22 effective limits the inrush current and so improves stability of the power supply and reduces transient voltage drops that may affect or break down other loads. This will eliminate the need of over dimension of the power supply system which results in reduce capital expenditure investment in power supply capacity, charge meter, circuit breaker and power wire line capacity etc..and extend the service life of the motor or compressor effectively.
    RJ-RSSU380KW22 is suitable for all three-phase air conditioner and heat pump and motor with horse power less than 22kw


    Features


    ● Limits inrush current
    ● Eliminates current surges & voltage drops
    ● Extends motor/compressor service life with built-in electronic overload protective relay
    ● Integral bypass contactor reduces heat generation
    ● Produces smoother starts and stops by controlling torque
    ● Reduces vibration and mechanical damage
    ● Relieves shock and drive train stress on startup
    ● Easy to wire and install and decreases equipment downtime
    ● High reliability and long life

    Wiring Instruction


    RJ-RSSU380KW22 soft start controller adopts terminal block connection mode, the connection is convenient and reliable, and the control circuit is connected by screw fastening terminal. The bypass is external bypass mode, which makes the circuit work more reliably.

    ● KW1 is the main contact of the open circuit AC contactor
    ● KM1 is the coil of the open circuit AC contactor
    ● KW2 is the main contact of the bypass AC contactor
    ● KM2 is the coil of the bypass AC contactor
    ● QA1 is the AC circuit breaker
    ● KR is a thermal protection relay, and its common open point No. is used in this circuit
    ● !RUN is the boot signal, the switch is on when power is on, and the switch is off when power is off.
    ● L1, L2, L3 are connection terminals of three phase power supply
    ● R, S, T are input terminals, connect with KW1 and QA1
    ● U, V, W are output terminals, connect with the load (only resistance or inductive load, can not receive capacitive load!!!)
    ● L and N are power control terminals. I1 is operation input control terminal. I2 is protection input terminal, and this terminal can not be connected in general applications
    ● COM1 is the common contact of relay 1. NO1 is the normally opened contact of relay 1. NC1 is the normally closed contact of relay 1. Relay controls the bypass contactor in the second circuit, the capacity is 2A/250VAC.
    ● COM2 is the common contact of relay 2. NO2 is the normally opened contact of relay 2. NC2 is the normally closed contact of relay 2. Relay controls the bypass contactor in the second circuit, the capacity is 2A/250VAC.

    1. Encoder and code switch


    A. Four bit code switch (S2)
    ● 0000 indicates a constant rise from 150V
    ● 1000 indicates soft stop function
    ● 0100 indicates step rise (S3 is step voltage setting)
    ● 0001 indicates a constant rise from 100V
    ● 0010 indicates a constant rise from 250V
    ● 0011 indicates a constant rise from 300V
    B. Encoder input function
    ● Voltage is selected as step up (S3)
    The setting value from 0000~1111 is 150v~310v, and 10V is a voltage unit;
    ● Soft start time choice (S1)
    From the 0000~1111 set as the "biggest soft starting time (soft starter output voltage reaches the maximum output voltage)" for 2s~17s, with 1s as a unit of time. But the actual soft starting time according to the load of the motor to decide, because when the output voltage reaches the maximum value, or when the motor runs normally (the speed reaches the rated value), it will be out of soft start state. It is shown that if the output voltage of the soft starter does not reach the maximum value, if the motor has been in normal operation, it will also be out of soft start state (soft start into the bypass operation state).

    2. Function indicator lamp


    ● D19: Power indicator (red), light will be on as soon as the power is on.
    ● D20: Switch status indicator (red), on / off signal
    ● D21: Switch status indicator (red), protection signal
    ● D22: Relay status indicator (red), output bypass relay
    ● D23: Relay status indicator (red), output open circuit relay
    ● D24: Program control light (red), soft start status indicator light
    ● D25: Program control light (red), soft stop status indicator light
    ● D26: Program control light (red), running indicator lamp
    ● D27: Program control light (red), input phase missing indicator light
    ● D28: Program control light (red), load wiring error indicator light
    ● D29: Program control indicator (red), protection status indicator

    Electric parameters


    ● Applicable compressor power: 380V/22KW/3PH (Rated current below 40A)
    ● Operating Voltage Range: 340~460VAC
    ● Control voltage: 220VAC(RJ-RSSU380KW22-L2)
    ● Control voltage: 380VAC(RJ-RSSU380KW22-L3)
    ● Rated operational current: 40A
    ● Starting current: ≤120A/10S (Rated operating current within 3 times)
    ● Surge current resistance: 300A/300mS
    ● Depletion current: ≤22mA
    ● Dissipation power: <5VA
    ● Soft start time: ≤10s
    ● Performance period: 45 thousand hours (within rated operating temperature range)
    ● Number of starts: 100 thousand times (normal environment, the interval is not less than 3 minutes)

    Environmental parameters


    ● Operating temperature range: -20~+65℃
    ● Flame retardation: Insulating materials have flame retardant properties
    ● Relative humidity: 0—95%
    ● Shock resistance: 200m/s2 11ms
    ● Anti-knock: 10~55mm (double amplitude 1.5mm)
    ● Rust-resisting property: Each metal component can withstand salt spray test for at least 24 hours

    Size and weight


    ● Size: 222*162*100mm (L*W*H)
    ● Weight: about 1.65 kg


    Terminal parameter


    ● R, S, T
    This is the three-phase power supply input terminals, the internal is three way SCR step-down circuit, input current capacity: no more than 150A/10s
    ● U, V, W
    Soft starter output terminals can only be connected to resistive or inductive load, not capacitive load. Output current capacity: no more than 150A/10s
    ● L, N
    Soft starter power supply, power: 3W
    ● I1, I2
    Switching input (photoelectric isolation), input: 100v~250VAC/DC.
    ● COM1, NC1, NO1, COM2, NC2, NO2
    Switch output (relay contact), output: 5A/250VAC, 5A/30DC